Environmental Monitoring EMCU-1-1B - Servertech

Ever increasing densities of vertically racked servers conserve valuable floor space in the data center, but the resulting power consumption and heat dissipation create new concerns for data center managers. Environmental Monitoring, particularly temperature & humidity, is a must for any sensitive infrastructure. Monitoring temperature in equipment cabinets is vital to the server's performance and controlling infrastructure cooling costs.

Temperature and Humidity Probe 

Sentry intelligent CDUs, Smart and Switched, support two external probes for measuring temperature and humidity.  Each of these probes' data can be viewed via the built-in firmware on the CDU. Receive SNMP-based alert notifications when conditions exceed defined thresholds.  By bundling intelligent power information (provided by the CDU) and environmental information (provided by the probe) under one IP address on the network, you can save on the cost of additional IP addresses.  Each CDU pair supports TWO probes.  Add additional probes using the EMCU-1-1B. 

EMCU 

The Environmental Monitoring Control Unit (EMCU) monitors vital environmental conditions in the equipment cabinet. Prevent environmental conditions from exceeding recommended thresholds and protect the equipment cabinet's assets from harmful elements.

Each EMCU supports:

> 2 Additional temperature and humidity measurements
> Water sensor

> 4 Dry contact closure door sensors

The EMCU-1-1B assures network managers that environmental conditions are within dened tolerances and that unauthorized entry into the equipment cabinets does not go unnoticed. The EMCU-1-1B can be located in data centers, co-lo sites, web hosting facilities, telecom switching sites, POP sites, server closets, and any unmanned area that needs to be monitored. Install the EMCU-1-1B in the equipment cabinet and gain access to environmental conditions from a web or serial interface through one of Server Technology's IP address-able CDUs.

Cabinet Environment Status:
•Qty 2 dual-function Temperature (°C) & Humidity Probes (% RH)
•Water & fluid detection probe

Cabinet Intrusion Detection:
•Supports 4 normally open or normally closed dry contact closure door sensors

Analog Input Sensor
•Supports supplementary analog sensor requiring power feed

Notification Warnings
•SNMP MIB integrates with NMS
•Thresholds & SNMP Traps to 2 destinations

IP Management
•HTML Web Interface
•Command Line Interface

Seamless Integration with all Server Tech Smart, Switched, POPS, and PTXL products
•Simple & fast installation
•No external Power source required
•Dedicated IP address not required
•No additional software required
•Flexible Zero U mounting